ST-LX38

¡¡ |
¡¡

¡¡
¡¡Instruction
¡¡
ST-LX38
INFRARED MOTION SENSOR SWITCH£¡
The
product is a new saving-energy switch
adopting the good sensitivity detector,
integrated circuit and SMT. It gathers
automatic, convenient, safe, saving-energy
and practical functions. The wide detection
field is made up of up and down, left and
right service field. It works by receiving
human motion infrared rays. When one enters
the detection fields, it can start the load
at once and identify day and night
automatically; Its installation is very
convenient and Its using is very wide. It
has the functions of the power indication
and the detection indication.
SPECIFICATIONS£º
Power source£º100V/AC~130V/AC
220V/AC~240V/AC
Power frequency:50~60Hz
Ambient light:<3LUX~2000LUX
adjustable
Time-delay £ºmin: 8sec¡À3sec
max:7min¡À2min
Rated load£º800W£¨110V/AC~130V/AC£©
1200W £¨220V/AC~240V/AC£© |
Detection motion
speed£º0.6~1.5m/s
Detection range£º180¡ã
140¡ã
110¡ã
Detection distance£º12m max(<24¡æ)
Working temperature£º-20~40¡æ
Working humidity£º<93%RH
Installation height£º0.5m~3.5m
Power consumption£º0.45W(static 0.1W) |
FUNCTION:
- Detection field: the detection field
(see the following diagram) is made up
of up and down, left and right service
field, it can be selected according to
the consumer¡¯s desire. But the moving
orientation has great relationship with
the sensitivity£»
- Can identify day and night: The
consumer can adjust ambient light when
LX38 works. It can work at night and in
the daytime when it is adjusted on the
¡°sun¡± position (max). It can work in the
ambient light less than 3LUX when it is
adjusted on the ¡°moon¡± position (min).
As for the adjustment pattern, please
refer to the testing pattern;
- Power and detection indication: The
indicator lamp can flash one time every
4sec after switching on the power. It
can flash 2 times every 1sec after it
receives the signals. At the same time,
it can show if the sensor is normal for
the detection and the power£»
- Time-Delay is added continually:
When it receives the second induction
signals after the first inductor, it can
compute time once more on the rest of
the first time-delay basic. (Set time).
- Time ¨CDelay is adjustable: It can be
set according to the consumer¡¯s desire.
The minimum time is 8sec¡À3sec. The
maximum is 7min¡À2min.
INSTALLATION
£¨see the following diagram£©
- Switch off the power£»
- Screw off the nail on the bottom.
Open the wire hole. The power wire and
the load wire are bored in the bottom£»
- Fix the bottom on the selected
position with the inflated screw£»
- Connect the power and the load into
the connection-wire column according to
the sketch diagram£»
then you can test it¡£
 
¡¡ |

¡¡ |
¡¡
- Fix the sensor on the bottom, please
screw on the nail and switch on the
power.
CONNECTION-WIRE DIAGRAM£¨see
the right figure£©
TEST£º
- Turn the light-control knob
clockwise on the maximum(sun), turn the
time knob clockwise on the minimum£»
- When you switch on the power, the
load don¡¯t work and the indicator lamp
flash once 4sec. After 5~10sec, the load
works and the indicator lamp flash twice
1sec. Under the conditions of no
inductor signals, the load should stop
working within 5~30sec, the indicator
lamp should flash still once 4sec;

¡¡ |
- After the first is out, make it
sense again after 5~10sec. The load
should work and the indication flash
speed is two times in 1sec. The load
should stop working within 5~15sec;
- Turn ambient light knob
anti-clockwise on the minimum. If it is
adjusted in the less than 3LUX, the
inductor load should not work after load
stop working. If you cover the detection
window with the opaque objects (towel
etc), the load work .under the
conditions of no inductor signals, the
load should stop working within 5~15sec£»
NOTES£º
- Electrician or experienced human can
install it£»
- The unrest objects can¡¯t be regarded
the installation basis-face£»
- In front of the detection window
there should be no hinder or unrest
objects effecting detection.
- Avoid installing it near air
temperature alteration zones for
example: air condition, central heating,
etc
- Please don¡¯t open the case for your
safety if you find the hitch after
installation.
SOME PROBLEM AND SOLVED WAY
- The load don¡¯t work£º
a.Check the power and the load£»
b.If the load is good£»
c.If the indicator lamp speed
quicken after sensing;
d.Please check if the working
light correspond to the ambient light¡£
- The sensitivity is poor£º
a.Please check if in front of
the detection window there is hinder
that effect to receive the signals¡£
b.Please check if the ambient
temperature is too high;
c.Please check if the signals
source is in the detection fields;
d.Please check the installation
height;
e.If the moving orientation is
right.
- The sensor can¡¯t shut automatically
the load:
a.If there is continual signal
in the detection fields;
b.If the time delay is set to
the longest;
c.If the power correspond to
the instruction.
d.If the air temperature change
near the sensor, for example air