Specification:
Power Source: 110~130V/AC
220~240V/AC
110~240V/AC
Power Frequency: 50~60Hz
Ambient Light: <3Lux~daylight
Detection Distance: 12m Max(<24 ¡æ)
Detection Angle: 180 degree
140 degree
Time Delay : 8Sec~8Min(adjustable)
Working Temperature: -20~+40¡æ
Rated load: 1200W(220~240V/AC)
800W(110~130V/AC)
Power Consumption: 0.45W (static 0.1W)
Installation Height: 0.5m-3.5m
Detection Motion Speed: 0.6-1.5m/s
Working Humidity: <93%RH
IP44
ST-LX39

¡¡
¡¡

Instruction
ST-LX39 Infrared motion sensor switch
This
product is a new type of energy-saving lighting switch,
it adopts high sensitivity detector, integrate circuit
and SMT; It gathers automatic, convenient, safe,
energy-saving, practical functions; It has wide
detection range made up of up and down, left and right
service field; It utilizes human motion infrared rays as
control signal sources, when one enters the detection
field, it will start the controlled load at once; It can
identify day and night automatically; It is easy to
install and its usage is wide; It has the function of
power indication and detection indication.
SPECIFICATION:
¡¡
Power source:220V/AC~240V/AC110V/AC~130V/AC
Detection distance: 12m max(<24¡æ)
Detection angle: 180 ¡ã
140¡ã
Power frequency: 50~60Hz
Ambient light:<3LUX~daylight (adjustable)Working
temperature:-20~40¡æ |
Time-delay:min:8s¡À3sMax:7min¡À2min
Working humidity:<93%RH
Installation height:0.5m¡À3.5m
Rated load:1200W
(220V/AC~240V/AC)800W(100V/AC~130V/AC)
Power consumption:0.45W (static 0.1W)
Detection motion speed:0.6-1.5m/s |
¡¡
FUNCTION:
- Detection field: The wide detection range is
made up of up and down, left and right (see the
following diagram), the detection range could be
adjusted according to your desire, but the moving
orientation in detection field has great relation
with the sensitivity;
- Identify day and night automatically: The
ambient light of LX39 could be adjusted according to
your desire: when turn to SUN (max), it will work
day and night, when turn it to MOON (min), it will
only work in the ambient light less than 3LUX. As
for adjustment, please refer to testing way;
- Time-delay is added continually: When it
receives the second induction signals after the
first induction, it will compute time once more on
the rest of the first time-delay basis (set time);
- Time-delay is adjustable: It can be set
according to your desire, the minimum is 8s¡À3s,the
maximum is 7min¡À2min.
¡¡
 |
|
Correct orientation
|
Incorrect moving orientation
|
¡¡
Diagram 1
INSTALLATION (See the following diagram)
- Shut off power;
- Loosen the screw on the bottom lid, open the
wiring hole, pass the wire of power and load through
the bottom lid;
- Fix the bottom lid with inflated screw on the
selected position;
- Connect the power and load wire into
connection-wire column according to the connecting
figure;
Put the sensor on the bottom lid, twist the screw
tightly then electrify it and test it.

¡¡
CONNECT-WIRE
FIGURE(See the right)
TEST:
- Turn the light-control knob clockwise to the
maximum (SUN), turn time knobanti-clockwise to the
minimum;
- Switch on power, the controlled load should not
work, under the no induction signal condition, the load
should stop work within 5-30sec;
- Make it sense again 5-10sec later since the
first is out, the load should work, the load should
stop working within 5-20sec;
- Turn LUX knob to minimum anti-clockwise, if you
test it when the ambient light is more than 3LUX,
the induction load would not work after the load
stops working; the load should work if you cover the
detection window with opaque object (towel etc),it
would be regular the load stops to work within
5-15sec under no induction signal condition.
NOTE:
- Should be installed by electrician or
experienced person;
- Avoid installing it on the unrest object;
- There should be no hindrance and moving objects
in front of the detection windows to effect
detection;
- Avoid installing it near air temperature
alteration zones such as air condition, central
heating, etc;
- Considering your safety, please do not open the
cover when you find the hitch after installation.
- If there is difference between instruction and
the function the product has, please give priority
to product and sorry not to inform you additionally.
SOME PROBLEM AND SOLVED WAY:
- The load do not work:
a: please check if the connection-wiring of
power and load is correct;
b: please check if the load is good ;
c: please check if the working light set
correspond to ambient light.
- The sensitivity is poor:
a: Please check if there has hinder in
front of the detection window to effectto receive
the signal;
b: Please check if the ambient temperature
is too high;
c: Please check if the induction signal
source is in the detection fields;
d: Please check if the installation height
corresponds to the height showed in the instruction;
e: Please check if the moving orientation
is correct.
- The sensor can not shut off the load
automatically:
a: Please check if there is continual
signal in the detection field;
b: Please check if the time delay is the
longest;
c: Please check if the power correspond to
the instruction;
d: Please check if the temperature near the
sensor change obviously, such as air condition or
central heating etc.
|