HomeAbout Us News ProductsHonors Tech Supports RecruitFeedbackServices
¡¡
PRODUCTS
Smoke Detector
PIR Lamp
Fire Alarm
Audio Product
Parking sensor
Gas Detector
Alarm Siren
Lamp Sensor
Alarm Sensor
Wireless Home Security
Emergency Button
Magnetic Switch
Infrared Detector
Light-Control Switch
Strobe Light
Heat Sensitive Alarm

¡¡

About us
Company Profile
R & D
Manufacturing
Honors
Our Partners
Contact us

Link Popularity

Google
Yahoo
Alibaba
Baidu
MSN
Myspace
QQ
Sina
Ebuy
163


|SECUTRONIC TECHNOLOGY|

ALARM SECURITY PRODUCTS

Burglar Alarm and
Car Alarm & Accessories
Offering you with Real Qualigy

The first priority of Secutronic Technology Co., Ltd support services is to supply every business, organization, and individual to be more successful with Secutronic Products.
Standalone and Fitting Lamp Sensor-- Wall surface sensor ST-LX39

¡¡

Specification:

Power Source: 110~130V/AC
220~240V/AC
110~240V/AC
Power Frequency: 50~60Hz
Ambient Light: <3Lux~daylight
Detection Distance: 12m Max(<24
¡æ)
Detection Angle: 180 degree
140 degree
Time Delay : 8Sec~8Min(adjustable)
Working Temperature: -20~+40
¡æ
Rated load: 1200W(220~240V/AC)
800W(110~130V/AC)
Power Consumption: 0.45W (static 0.1W)
Installation Height: 0.5m-3.5m
Detection Motion Speed: 0.6-1.5m/s
Working Humidity: <93%RH
IP44

ST-LX39

Infrared Motion Sensor
¡¡


¡¡

Instruction

ST-LX39 Infrared motion sensor switch

This product is a new type of energy-saving lighting switch, it adopts high sensitivity detector, integrate circuit and SMT; It gathers automatic, convenient, safe, energy-saving, practical functions; It has wide detection range made up of up and down, left and right service field; It utilizes human motion infrared rays as control signal sources, when one enters the detection field, it will start the controlled load at once; It can identify day and night automatically; It is easy to install and its usage is wide; It has the function of power indication and detection indication.

SPECIFICATION:

¡¡

Power source:220V/AC~240V/AC110V/AC~130V/AC
Detection distance: 12m max(<24¡æ)
Detection angle: 180 ¡ã
140¡ã
Power frequency: 50~60Hz
Ambient light:<3LUX~daylight (adjustable)Working temperature:-20~40¡æ

Time-delay:min:8s¡À3sMax:7min¡À2min
Working humidity:<93%RH
Installation height:0.5m¡À3.5m
Rated load:1200W (220V/AC~240V/AC)800W(100V/AC~130V/AC)
Power consumption:0.45W (static 0.1W)
Detection motion speed:0.6-1.5m/s

¡¡

FUNCTION:

  • Detection field: The wide detection range is made up of up and down, left and right (see the following diagram), the detection range could be adjusted according to your desire, but the moving orientation in detection field has great relation with the sensitivity;
  • Identify day and night automatically: The ambient light of LX39 could be adjusted according to your desire: when turn to SUN (max), it will work day and night, when turn it to MOON (min), it will only work in the ambient light less than 3LUX. As for adjustment, please refer to testing way;
  • Time-delay is added continually: When it receives the second induction signals after the first induction, it will compute time once more on the rest of the first time-delay basis (set time);
  • Time-delay is adjustable: It can be set according to your desire, the minimum is 8s¡À3s,the maximum is 7min¡À2min.

¡¡

Correct orientation
 
Incorrect moving orientation
¡¡

              Diagram 1

INSTALLATION (See the following diagram)

  • Shut off power;
  • Loosen the screw on the bottom lid, open the wiring hole, pass the wire of power and load through the bottom lid;
  • Fix the bottom lid with inflated screw on the selected position;
  • Connect the power and load wire into connection-wire column according to the connecting figure;

  • Put the sensor on the bottom lid, twist the screw tightly then electrify it and test it.


¡¡

CONNECT-WIRE FIGURE(See the right)

TEST:

  • Turn the light-control knob clockwise to the maximum (SUN), turn time knobanti-clockwise to the minimum;
  • Switch on power, the controlled load should not work, under the no induction signal condition, the load should stop work within 5-30sec;
  • Make it sense again 5-10sec later since the first is out, the load should work, the load should stop working within 5-20sec;
  • Turn LUX knob to minimum anti-clockwise, if you test it when the ambient light is more than 3LUX, the induction load would not work after the load stops working; the load should work if you cover the detection window with opaque object (towel etc),it would be regular the load stops to work within 5-15sec under no induction signal condition.

NOTE:

  • Should be installed by electrician or experienced person;
  • Avoid installing it on the unrest object;
  • There should be no hindrance and moving objects in front of the detection windows to effect detection;
  • Avoid installing it near air temperature alteration zones such as air condition, central heating, etc;
  • Considering your safety, please do not open the cover when you find the hitch after installation.
  • If there is difference between instruction and the function the product has, please give priority to product and sorry not to inform you additionally.

SOME PROBLEM AND SOLVED WAY:

  • The load do not work:
             a: please check if the connection-wiring of power and load is correct;
             b: please check if the load is good ;
             c: please check if the working light set correspond to ambient light.
  • The sensitivity is poor:
             a: Please check if there has hinder in front of the detection window to effectto receive the signal;
             b: Please check if the ambient temperature is too high;
             c: Please check if the induction signal source is in the detection fields;
             d: Please check if the installation height corresponds to the height showed in the instruction;
             e: Please check if the moving orientation is correct.
  • The sensor can not shut off the load automatically:
             a: Please check if there is continual signal in the detection field;
             b: Please check if the time delay is the longest;
             c: Please check if the power correspond to the instruction;
             d: Please check if the temperature near the sensor change obviously, such as air condition or central heating etc.