LX-108A
Smoke Detector
Product
Features:
Working Current:
¡Ü5uA
Alarm Sound: ¡Ý85db(3m)
Temperature: -10~+40¡æ
Operating Uoltage:
DC9V
Low Battery Alert Remain: 7-15 days
SMOKE ALARM
INSTRUCTION
WELCOME USING LX-108
SMOKE ALARM
The
product adopts ionization room with advanced
single-power twin-room structure in the world, 9V
battery as power source, and economizes electricity. It
is used in single room in family. For your safety, you¡¯d
better install one alarm in every room. Please read the
instruction carefully before you use it, do not open the
alarm easily to avoid being irregular for working. You
cannot replace any component in this product except for
battery to avoid irregular working, if there is any
wrong with it, please contact the supplier promptly.
FUNCTION:
- The ionization room adopts single-power
twin-room structure in the world, has high
sensitivity and good anti-jamming performance,
- Adopts special control CMOS chip gathering high
compositive degree, steady performance and long
using life;
- Tiny power consumption, battery as power source,
safety, convenient installation, not join other
power source,
- Alarm function of low voltage, reminding you to
replace the battery on time;
- Periodic testing: We suggest that you¡¯d better
do a simulation testing every week or every 15 days
to guarantee your damage declining to the lowest
when danger happen, you only press the testing
button gently for this work;
- Convenient installation: Do not effect by the
position of power, spare the trouble of drawing
power source, please refer to ¡°installation way and
note¡± for the installation;
- Double alarm: Adopts double alarm of
sound-audio, it can attend the common or lower
audition user at the same time.
SPECIFICATION:
Power source: DC9V(cascading battery
power)
Working current:: surveillant current
<10uA,
alarm current <10mA;
Alarm sound: >85dB
Ambient temperature: -10¡æ~50¡æ
Ambient humidity: ¡Ü95%(40¡À2¡æ)
INSTALLATION AND NOTE:
- After tryout for the detector, please replace
the battery one time every year, otherwise, it will
effect the working because of the low voltage of
battery;
- There is no component to replace by yourself
except for battery in detector, if there is any
wrong with the product, please contact our service
department;
- Do not place it at the high humidity, dusty
position;
- You should install it after the room is
decorated; it should be placed in dustproof,
moistureproof, mildewproof position;
- The detector should be installed 1.5m away from the
blast mouth of air conditioner, there is no hinder 0.5m
in front of detector;
- The detector is suitable for level installation,
if you want to install slantways, the degree is less
than 45;
- Having a test for the detector termly. When
testing, please press the testing button, the buzzer
in the detector will chime within 10sec; output the
testing signal at the same time and collect the
alarm to emit alarm of sound-audio;
- If the detector sound one time every minute, please
replace the battery promptly. The battery should be 9V
cascading.
INSTALLATION AND TESTING:
-
The
distance between installation holes on the base is
80mm; fix two wooden bolts (¦µ3¡Á12) on the selected
position, then push the detector.
- It will be sound-audio alarm when electrifying
alarm first, stop alarming within 10sec, then press
the testing button after 60sec,if the alarm is
sound-audio alarm, it can be used, if it do not
alarm or stop alarming, please contact the supplier
.Do not open your alarm by yourself.
NOTE:
The smoke alarm cannot be substitute for fire alarm
system; it is not sensitive to flammable gas. We must
state that smoke is not secure substitute, at any time
it might be failure; so you must test it periodically
and replace it every 5 years. Once there is accident, we
do not undertake any responsibility. |