| ST-LX-AL9 |
| ¡¡ |
¡¡ |
| ¡¡ |
Working Freqency:
315MHz or 433MHz
Power Sources: Dc9v(Batteries)
Detection Range(22¡æ):
100¡ã
Detection Distance: 11m(Max)
Work Temperature: -10~+40¡æ
Working Humidity:£¼93%RH |
|
ST-LX-AL9 SENSOR
INSTRUCTION
LX-AL9
is a new type of human infrared sensor, it adopts high
sensitivity detector and SMD technology. it gathers sense
and emission; when one enters its sense range, it sense and
at the same time it emit signal to suited receiver( any
receiver of our company).
FEATURES
- Battery powered and no wiring required;
- Tamper design, when the front cover is removed,
the unit will emit signal at once;
- LED indication: sense and emission indicator
SPECIFICATION
Power supply:DC9VSense motion speed:0.6~1.5m/s
Static current: 0.2mAWorking temperature: -20~40¡æ
Sense distance:11mRelative humidity:<93%RH
Sense angle:100¡ãInstallation height:2m
Emit distance:¡Ý50m
JUMPER SETTING (like following figure)
 
TEST
- Set JP1 and JP2 on;
- Fix 9V battery, after 60s the sensor enters
working state;
-

Move along the lens tangent in the sense field, the
sensor sense(the sense LED works), and then it emit
signal to suited receiver( emission LED works), the
emitting time should be 3~4s, if sense continually,
only 20s later after it emit for the previous time,
it emit again.
- Tamper test: open the front cover, it will emit
signal and the emitting LED on.
ATTENTION
- You should choose installation position
where the moving object can move breadthwise
with sensor(like right diagram);
- The unit should be checked by walking test
periodically to assure proper operation;
- lf the unit does not work properly,
immediately replace the batteries and retest the
unit ;
- Avoid installing the unit on the metal base;
- No block is allowed between the unit and desired
area of detection;
- The unit and its detection area should not be
exposed to direct sunlight, heaters, electric fans,
etc.
|